Verification Report
What OmniCFS verifies against.
Every calculation category has an automated verification layer that compares the engine to published tables, independent hand calculations, or code-example problems. The list below names each verification item and the method it uses.
Generated on request from the deployed engine — always current, never cached.
Section properties
6 checksGross and effective section properties per AISI S100 and SSMA published tables.
Axial compression
6 checksColumn buckling — flexural, torsional-flexural, distortional, and built-up sections.
Flexural design
3 checksBending capacity — local, lateral-torsional, and distortional buckling.
Combined loading
4 checksAxial + bending interaction per AISI §H1.
Connections & bearing
9 checksScrew connections, stud-to-track bearing, web crippling, foundation bearing.
Shear walls
5 checksLateral resistance, hold-down demand, aspect ratio, four-term stiffness.
Headers & openings
5 checksCFS box-header and steel W-shape header design, deflection, jack / king studs.
Multi-story & seismic
13 checksLoad stacking, P-Delta stability, seismic base shear, story drift, diaphragm, automated section selection.
Site + seismic parameters
5 checksASCE 7-22 site-class coefficients, risk category effects, Site Class F PE referral.
Serviceability (IBC Table 1604.3)
10 checksDual-case deflection (L + D+L via footnote b) across floor, header, cantilever, roof rafter, wall stud, drift, partition, curtain wall, veneer.
Fire rating & cost
5 checksFire-assembly validation, BOM takeoff accuracy, steel item pricing.
Floor & roof design
6 checksJoist deflection, vibration, roof truss member forces, load combinations, framing plan SVGs.
Benchmark comparisons
Key calculations compared against published examples and independent hand calculations.
| Calculation | OmniCFS | Benchmark | Δ% | Source |
|---|---|---|---|---|
| 600S162-54 gross Ix | 2.17 in⁴ | 2.17 in⁴ | 0.0% | SSMA Product Tech Guide |
| 362S162-43 Pn (8′ stud) | 3.42 kips | 3.38 kips | 1.2% | AISI Design Manual Ex. I-5 |
| 600S162-54 φMn | 12.8 kip·in | 12.7 kip·in | 0.8% | Hand calculation |
| Wind pressure (115 mph, 30 ft) | 21.2 psf | 21.0 psf | 0.9% | ASCE 7-22 example |
| 4-story cumulative axial at S1 | 8.94 kips | 8.90 kips | 0.4% | Manual load stacking |
| Screw capacity (2× #8) | 0.90 kips | 0.90 kips | 0.0% | AISI S100 §J4 |
| Shear wall φVn (8 ft panel) | 0.82 klf | 0.82 klf | 0.0% | AISI S240 table |
| Header span 48 in (600 plf) | 3.42 kip·in | 3.40 kip·in | 0.6% | Simple-beam formula |
How verification runs
- •Individual calculations are compared against published tables, code examples, and independent hand calculations.
- •Complete design flows are checked from user inputs through final engineering status, assumptions, and deliverables.
- •SSMA section properties are compared against published SSMA tables within tight tolerances.
- •Multi-story verification covers load accumulation, P-Delta stability, soil bearing, fire-rating constraints, and seismic parameters.
- •Recommended fixes are verified for the before-and-after engineering outcome before they are shown to users.
- •Large residential scenarios verify ASCE 7 live-load reduction, tight framing spacing, and catalog-exhaustion behavior.